The power windows operate by using the power window regulator master switch assembly, power window regulator switch assembly, rear power window regulator switch assembly LH or rear power window regulator switch assembly RH.
The power window regulator master switch assembly, power window regulator switch assembly, rear power window regulator switch assembly LH and rear power window regulator switch assembly RH connect the same power supply and ground lines.
Inspect the fuses for circuits related to this system before performing the following procedure.
| *a | Front vie of wire harness connector
(to Instrument Panel Junction Block Assembly) |
Disconnect the instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-9 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-1 - Body ground | Always | 11 to 14 V |
| 3C-44 - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly) |
Disconnect the power window regulator master switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J5-1 (E) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J5-6 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the power window regulator master switch assembly.
Inspect the power window regulator master switch assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3C instrument panel junction block assembly connector.
Disconnect the J5 power window regulator master switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3C-11 - J5-6 (B) | Always | Below 1 Ω |
| J5-1 (E) - Body ground | Always | Below 1 Ω |
| 3C-11 or J5-6 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG